6.2.1.15. monitoring-engine
6.2.1.15.1. Introduction
The monitoring-engine
command of the show
subgroup enables displaying the advanced options of the GCap detection engine configuration:
the start-timeout grace period
the grace period when the engine is stopped (stop-timeout)
the status of the sanity checks
6.2.1.15.2. Prerequisites
User: setup
Dependencies: the detection engine must be switched off
6.2.1.15.3. Command
show monitoring-engine {start-timeout|stop-timeout|sanity-checks}
6.2.1.15.4. Example of displaying the default value of the start-timeout
Enter the following command.
(gcap-cli) show monitoring-engine start-timeout
Validate.
The system displays the current value.
Monitoring Engine Options:
Start timeout: 600s
6.2.1.15.5. Example of displaying the default value of the stop-timeout
Enter the following command.
(gcap-cli) show monitoring-engine stop-timeout
Validate.
The system displays the current value.
Monitoring Engine Options:
Stop timeout: 300s
6.2.1.15.6. Example of displaying the status of the verification check
Enter the following command.
(gcap-cli) show monitoring-engine sanity-checks
Validate.
The system displays the current value.
Monitoring Engine Options:
Sanity checks enabled
The system reports that the control system is active.
The detection engine will only start after it verifies that at least one monx
capture interface is activated and a cable is connected.