6.2.6. pairing
6.2.6.1. Introduction
The pairing command enables configuring the IPsec pairing with the GCenter.
6.2.6.2. Prerequisites
User: setup
Dependencies:
the detection engine must be switched off
the network interfaces must be correctly configured
the IP address of the GCenter must be entered via the
set gcenter-ipcommandthe compatibility of the GCenter must be entered via the
set compatibility-modecommand
6.2.6.3. Command
pairing fingerprint FINGERPRINT otp OTP
6.2.6.4. Example of pairing a GCap version 2.5.4.0 with a GCenter
Retrieve the FQDN (hostname + domain) of the GCap via the
show statuscommand.(gcap-cli) show status
Go to the GCenter WEB interface to add the full FQDN (Fully Qualified Domain Name) of the probe
For more information, please refer to the GCenter documentation.Enter the SSH fingerprint of the GCenter in the
pairingcommand.Enter the generated OTP in the
pairingcommand.(gcap-cli) pairing fingerprint XXX otp XXX
Validate the pairing with the
show statuscommand.(gcap-cli) show status
For more information on this procedure, refer to the Pairing procedure between a GCap and a GCenter.