6.2.1.15. monitoring-engine

6.2.1.15.1. Introduction

The monitoring-engine command of the show subgroup enables displaying the advanced options of the GCap detection engine configuration:

  • The start-timeout grace period

  • The grace period when the engine is stopped (stop-timeout)

  • The status of the sanity checks


6.2.1.15.2. Prerequisites

  • User: setup

  • Dependencies: the detection engine must be switched off


6.2.1.15.3. Command

show monitoring-engine {start-timeout|stop-timeout|sanity-checks}


6.2.1.15.4. Example of displaying the default value of the start-timeout

  • Enter the following command.

    (gcap-cli) show monitoring-engine start-timeout
    
  • Validate. The system displays the current value.

    Monitoring Engine Options:
    Start timeout: 600s
    

6.2.1.15.5. Example of displaying the default value of the stop-timeout

  • Enter the following command.

    (gcap-cli) show monitoring-engine stop-timeout
    
  • Validate.
    The system displays the current value.

    Monitoring Engine Options:
    Stop timeout: 300s
    

6.2.1.15.6. Example of displaying the status of the verification check

  • Enter the following command.

    (gcap-cli) show monitoring-engine sanity-checks
    
  • Validate.
    The system displays the current value.

    Monitoring Engine Options:
    Sanity checks enabled
    

    The system reports that the control system is active.
    The detection engine will only start after it verifies that at least one monx capture interface is activated and a cable is connected.