6.2.1.15. monitoring-engine
6.2.1.15.1. Introduction
The monitoring-engine
command of the show
subgroup enables displaying the advanced options of the GCap detection engine configuration:
The start-timeout grace period
The grace period when the engine is stopped (stop-timeout)
The status of the sanity checks
6.2.1.15.2. Prerequisites
User: setup
Dependencies: the detection engine must be switched off
6.2.1.15.3. Command
show monitoring-engine {start-timeout|stop-timeout|sanity-checks}
6.2.1.15.4. Example of displaying the default value of the start-timeout
Enter the following command.
(gcap-cli) show monitoring-engine start-timeout
Validate. The system displays the current value.
Monitoring Engine Options: Start timeout: 600s
6.2.1.15.5. Example of displaying the default value of the stop-timeout
Enter the following command.
(gcap-cli) show monitoring-engine stop-timeout
Validate.
The system displays the current value.Monitoring Engine Options: Stop timeout: 300s
6.2.1.15.6. Example of displaying the status of the verification check
Enter the following command.
(gcap-cli) show monitoring-engine sanity-checks
Validate.
The system displays the current value.Monitoring Engine Options: Sanity checks enabled
The system reports that the control system is active.
The detection engine will only start after it verifies that at least onemonx
capture interface is activated and a cable is connected.